Explosion-Proof Lighting Specification

For Zone 1 & Zone 2 hazardous areas with explosive air mixtures IIA, IIB, IIC, as platform boundary lights and vessel deck illumination.

Attribute LM-EXD-CL01 LM-EXD-CL02
Type LM-EXD-CL01 LM-EXD-CL02
Voltage AC50-265V 50Hz (Compatible with DC24V, AC/DC36V)
Power 10W / 20W / 30W 20W / 30W / 40W
Power Factor ≥0.95
Illuminant LED
Light Effect 100 lm/W
Color Rendering Index ≥80
Color Temperature 2700K-6000K
Protection Class IP65
Corrosion Protection WF2
Installation Way Ceiling-mounted / Suspension / Wall-mounted / Guardrail / Flange
Installation Height 2.5-15 meters (Different power options for different heights)
Cable Entry G1/2" thread entry, suitable for Ø4-8mm cables
Standards GB3836.1, GB3836.3, IEC60079-0, IEC60079-1, EN60079-0, EN60079-1
Weight 11kg 14.5kg
Explosion Proof Standard Ex de IIC T6 Gb / Ex tD A21 IP65 T80°C

Scope of Application

The light used for zone 1 zone 2 dangerous place, explosive air mixture HA, IB, IIC, at the illumination of platform boundary light and vessel deck.

Attribute UM-EDO-C103 UM-EDO-CUDE
Voltage AC 50~260V 50Hz (optional DC24V, AC/DC58V) AC 50~260V 50Hz (optional DC24V, AC/DC58V)
Power 20W/30W/40W/50W 20W/30W/40W/50W
Power Factor >0.95 >0.95
Illuminant LED LED
Light Effect 90 lm/W 90 lm/W
Color Rendering Index >80 >80
Color Temperature 2700K~6000K 2700K~6000K
Protection Class IP65 IP65
Corrosion Protection Type WIP WIP
Installation Way Ceiling-mounted, Suspension type, Wall-mounted, Guardian Type, Range type Ceiling-mounted, Suspension type, Wall-mounted, Guardian Type, Range type
Installation Height 2.5~15 meters 2.5~15 meters
Cable Entry G3/4", suitable for φ10~φ14mm cable G3/4", suitable for φ10~φ14mm cable
Execution Standards GB4386.1, GB8386.3, EC60079-0, EC60079-1, EN60079-0, EN60079-1 GB4386.1, GB8386.3, EC60079-0, EC60079-1, EN60079-0, EN60079-1
Emergency -- 3W/50min
Weight 1.8kg 2.5kg
Explosion Proof Standard Ex de IIC T6 GB / Ex ID A21 IP65 TB0°C Ex de IIC T6 GB / Ex ID A21 IP65 TB0°C